Overview
Description
The DG EXP PN industrial vacuum cleaners are ideal for suction of dry dust which, under normal working conditions, can clog the filter, reducing suction performance for fine dust (the PN system is the ideal solution for construction dust, cement plants, surface treatment). The DG EXP PN are equipped with high surface area filter cartridges that are cleaned automatically and at set intervals by a reverse air filter cleaning system, allowing the operator to vacuum continuously until the container is completely full.
Features
Application
Packed solids and dust
Footprint
Industrial construction with high durability and easy maintenance
Material
Complete painted steel construction
Filter
Class M antistatic polyester cartridges with
integrated alternating pneumatic automatic cleaning
Features
Ex a Certified Side Channel Blower
Dust Tight
Compliance
Compliance with EN IEC 62784:2018 for zone 22
Technical specs
Technical details
| Unit of measure | Data | |
|---|---|---|
| Zone | ATEX Zone: 20 Internal/22 External | |
| Ex Category | 1/3D (20 int/22 ext) | |
| Marking | II 1/3D Ex h tb IIIC T135°C (Int) /T195°C (ext) Da/Dc | |
| Voltage | V | 400 |
| Power | kW | 6.30 |
| Frequency | Hz | 50 |
| Current Draw | A | 11.80 |
| Inlet Diameter | mm | 80 |
| Bin Capacity | lt. | 100 |
| Noise Level (EN ISO 3744) | dB(A) | 75 |
| Dimensions | cm | 66x120x213h |
| Weight | Kg | 180 |
| Electrical Protection Rating | IP | 65 |
| Max Vacuum Rate | 3.600 | |
| Continuous Duty Vacuum | 3.200 | |
| Max Airflow | 530 | |
| Motor Type | Three-phase Turbine |
Certifications
Filter class
| Unit of measure | Data | |
|---|---|---|
| Primary Filter | Cartridge | |
| Number of cartridges | 3 | |
| Primary filter load | m³(m²/h) | 66 |
| Primary filter surface area | cm² | 80.000 |
| Primary filter diameter | mm | 150 |
| Primary filter media | Polyester | |
| Primary filter class (IEC 60335-2-69) | ANT M | |
| Filter cleaning system | PN - Automatic compressed-air filter cleaning system during vacuuming | |
| HEPA absolute filter | Included | |
| Absolute filter surface area | cm² | 52.000 |
| Absolute filter class (EN 1822-5) | H14 con 99,995% di efficienza secondo il metodo MPPS | |
| Relief valve | Included |
Certifications
Documentation
Publications
PDF, 185.17 KB
PDF, 342.37 KB