The MTL 202 ACD is the single-phase industrial vacuum cleaner certified ACD for the safe collection of combustible dust in non-ATEX classified zones, offering protection above the standard for non-continuous applications.
The powerful 2.2 kW head with antistatic class M cartridge filter of 30,000 cm² and Dustop cleaning system ensures high performance with efficient filtration even with very fine dust. The 20-liter AISI 304 stainless steel tank with quick-release system makes emptying safe and easy. The H14 Absolute Filter included as standard ensures maximum purity of the air expelled into the work environment.
Ideal for production departments in the chemical, pharmaceutical, food, and plastics industries that handle combustible dust in non-ATEX classified environments. The ACD classification represents the optimal balance between regulatory compliance, operational safety, and investment, for all companies that need to manage combustible dust without formally defined ATEX zones.
Features
Dust and solids
Compact and mobile
Stainless steel tank AISI304
Class M antistatic, integrated Dustop filter cleaning system
Certified Ex tb Dust Tight IP64 head, tested ATEX accessories and non-metallic parts
Technical specs
Technical details
| Unit of measure | Data | |
|---|---|---|
| Zone | Non-classified environment | |
| Ex Category | 1/- D (ACD) | |
| Marking | II 1/-D Ex h IIIC T80°C (Internal) Da/- | |
| Voltage | V | 230 |
| Power | kW | 2.20 |
| Frequency | Hz | 50/60 |
| Current Draw | A | 10.00 |
| Inlet Diameter | mm | 50 |
| Bin Capacity | lt. | 20 |
| Noise Level (EN ISO 3744) | dB(A) | 74 |
| Dimensions | cm | 51x57x104h |
| Weight | Kg | 35 |
| Max Vacuum Rate | 2.500 | |
| Continuous Duty Vacuum | 2.500 | |
| Max Airflow | 360 | |
| Motor Type | Single-phase Bypass |
Certifications
Filter class
| Unit of measure | Data | |
|---|---|---|
| Primary Filter | Cartridge | |
| Primary filter load | m³(m²/h) | 120 |
| Primary filter surface area | cm² | 30.000 |
| Primary filter diameter | mm | 360 |
| Primary filter media | Polyester | |
| Primary filter class (IEC 60335-2-69) | ANT M | |
| Filter cleaning system | Dustop | |
| HEPA absolute filter | Standard | |
| Absolute filter surface area | cm² | 20.500 |
| Absolute filter class (EN 1822-5) | H14 con 99,995% di efficienza secondo il metodo MPPS |